TT-1200A Digital Turbine Temperature Test Set (RCM)

TT-1200A Digital Turbine Temperature Test Set (RCM)

Description: The Barfield TT1200A is a Digital Turbine Temperature Test Set.

Tags: Test Equipment, Miscellaneous Test Equipment, Temperature Testers

SKU: TT1200A

Description

The Barfield TT1200A is the latest digital turbine temperature test set, with many new features:

  • Microprocessor-based
  • Backlit alphanumeric display
  • User prompts
  • °F and millivoltage display
  • Temperature range to 1,372°C
  • 4 resistance and 4 insulation ranges and power comes from standard "C" batteries for all functions

This completely self-contained, battery-powered unit is housed in a new high-visibility ruggedized enclosure. The turbine temperature unit is designed with sufficient accuracy and range to be able to test the newest digital and glass cockpit indicators with simplicity of operation, direct reading, and multi-function versatility.

The TT1200A is specifically designed to accomplish all requirements for testing the aircraft Chromel-Alumel (K type) turbine temperature measuring systems. The Test Set can measure resistances down to 0.001W, measure insulation up to 200 MW, perform indicator run-outs with a resolution of 0.1°C or 1°C and a range of 1372°C, and can also display the equivalent °F or millivoltages and may be used as a master indicator as well.

Top Features

  • Microprocessor-based
  • Calibration Date available from the display with User Alerts to approaching Cal Date 
  • Backlit 16-Character Alphanumeric Display with User Prompts 
  • True 4-Wire Resistance Measurements 
  • Has °C, °F, and equivalent millivoltage displays 
  • Powered from long-lasting C cell batteries with Auto-Off feature to conserve batteries 
  • Timed Measurement with Display Hold feature for Resistance and Insulation Functions: No need to keep the pushbutton depressed

Temperature Measurement

  • Range: -200°C to 1372°C
  • Accuracy: ± 0.3°C (Typical at 25°C)

Resistance Measurement

  • 20W: 0 - 19.999W @ 0.001 W increments
  • 200W: 0 - 199.99W @ 0.01 W increments
  • 2KW: 0 - 1.9999KW @ 0.1 W increments
  • 20KW: 0 - 19.999KW @ 1 W increments
  • Accuracy: ± 0.05 % of reading ± 2 counts

Insulation Measurement

  • 200KW: 0 to 199.9 kW @ 0.1 kW increments
  • 2MW: 0 to 1.999 MW @ 1 kW increments
  • 20MW: 0 to 19.99 MW @ 10 kW increments
  • 200MW: 0 to 199.9 MW @ 1,001 kW increments
  • Excitation: 45V DC
  • Accuracy: ± 5 % of reading ± 2 counts

Physical Specifications

  • Dimensions: 7" x 11" x 10" (17.8 x 27.9 x 25.4 cm)
  • Weight: 7.3 lbs. (3.3 kg)